Filter systems for gaseous substances

Klepp-gas-filter-systems (KGF)

In manufacturing one thing is very common across all industries: harmful gasas, odors and vapors emitted during the production process. The effects on staff include headaches, conjunctival irritation, premature fatigue and damage to the respiratory organs or the central nervous system caused by inhalation of the substances.

Klepp gas filtration systems offer an ideal solution for permanent, optimal extraction and filtration of pollutants from gases, odors, solvents, adhesive and vapors.

Our practical extraction elements capture the air via armshaped suction pipes, suction vent channels, table-integrated extraction systems or completely customized designs to your application. A hose system or pipeline, that is individually optimized to your needs, safely feeds the extracted pollutants to the filter unit. The air contaminations are absorbed through a hepa filter in our filter system. In the second step the different gases are seperated by further integrated active carbon layers, optionally chemisorption or oxidation.

Our sustainable three-stage filtration system consisting of a pre-filter, particle filter and gas filter cleans the working air individually according to your application requirements. The remaining clean air can then be redirected into the work space. Customer value: reduction in heating costs.The gas filter of our Klepp gas filter systems can be refilled continuously and the exchange of the filters can be carried out independently or by our qualified staff in the course of maintenance.

Klepp gas filter systems offer the best protection for your employees and for the entire production space.

Adjustable

Our adjustable Klepp gas filter systems continuously regulate the air performance via an LED display and can thus be easily adapted to the current load for extraction of the pollutants. A visual signal combined with a full text display guides the operator intuitively through the required action and indicates upcoming maintenance. The count of operated hours and filter-status can also be accessed via the display.

Optionally, a remote on-off function can be implemented with the same control, and a pressure differential control can be supplied for the KGF803AK or the KGF1003AK.

Klepp gas filter unit

KGF 703-AK

Number of work stations2 – 4 (mobile unit)
Air performancevariable-speed (via display)
Released air volume390 m³/h
Effective air volume350 m³/h
Filterclass by EN 1822 standardZ line filter F9, exchangeable
Active carbon6.4 kg
Sound pressure level60.3 dB(A)
Klepp gas filter unit

KGF 803-AK

Number of work stations2 – 5 (mobile unit)
Air performancevariable-speed (via display)
Released air volume645 m³/h
Effective air volume400 m³/h
Filterclass by EN 1822 standardZ line filter F9, exchangeable
Active carbon6.4 kg
Sound pressure level66.8 dB(A)
Klepp gas filter unit

KGF 1003-AK

Number of work stations4 – 8 (mobile unit)
Air performancevariable-speed (via display)
Released air volume800 m³/h
Effective air volume730 m³/h
Filterclass by EN 1822 standardH13 exchangeable; optionally H14
Active carbon16.0 kg
Sound pressure level68.0 dB(A)
Klepp gas filter unit

KGF 1703-AK

Number of work stations6 – 15 (stationary)
Air performanceconstant (optionally SPS/DDS)
Released air volume1700 m³/h
Effective air volume1260 m³/h
Filterclass by EN 1822 standardH13 exchangeable; optionally H14
Active carbon42.0 kg
Sound pressure level69,6 dB(A)

Ecoline

Our constant Klepp gaseous filter systems guarantee you a constant air output and permanently ensure the optimum extraction performance. The On/Off operating switch and a control light are located on the control panel. An optical signal indicates the need for action and maintenance. Optionally, a remote on/off switch or a pressure difference control can be provided .

Attractive purchase costs are achieved by simplifying the operation of the KGF ecoline, with proven system quality. Contact us, we will be happy to advise you.

Klepp gas filter unit

KGF 703-AK eco

Number of work stations2 – 4 (mobile unit)
Air performanceconstant (not adjustable)
Released air volume390 m³/h
Effective air volume350 m³/h
Filterclass by EN 1822 standardZ line filter F9, exchangeable
Active carbon6.4 kg
Sound pressure level60.3 dB(A)
Klepp gas filter unit

KGF 803-AK eco

Number of work stations2 – 5 (mobile unit)
Air performanceconstant (not adjustable)
Released air volume645 m³/h
Effective air volume400 m³/h
Filterclass by EN 1822 standardZ line filter F9, exchangeable
Active carbon6.4 kg
Sound pressure level66.8 dB(A)
Klepp gas filter unit

KGF 1003-AK eco

Number of work stations9 (mobile unit)
Air performanceconstant (not adjustable)
Released air volume1020 m³/h
Effective air volume730 m³/h
Filterclass by EN 1822 standardH13 exchangeable; optionally H14
Active carbon16.0 kg
Sound pressure level68.0 dB(A)

EX Filter Systems

If you need to extract highly flammable gases and vapors, you require extraction systems in an explosion-proof design. Only this way you are safe from an unpleasent surprise. Our KGF-EX filter units are built in accordance with the directive for potentially explosive atmospheres, and are equipped with an appropriate Ex fan and corresponding components.

Klepp gas filter unit

KGF 803-AK EX

Number of work stations2 – 3 (mobile unit)
Air performanceconstant (not adjustable)
Released air volume420 m³/h
Effective air volume270 m³/h
Filterclass by EN 1822 standardZ line filter F9, exchangeable
Active carbon6.4 kg
Sound pressure level57.6 dB(A)
Klepp gas filter unit

KGF 1003-AK EX

Number of work stations4 – 8 (mobile unit)
Air performanceconstant (not adjustable)
Released air volume800 m³/h
Effective air volume560 m³/h
Filterclass by EN 1822 standardH13 exchangeable; optionally H14
Active carbon16.0 kg
Sound pressure level62.1 dB(A)
Klepp gas filter unit

KGF 1703-AK EX

Number of work stations6 – 15 (stationary)
Air performanceconstant (not adjustable)
Released air volume1700 m³/h
Effective air volume1180 m³/h
Filterclass by EN 1822 standardH13 exchangeable; optional H14
Active carbon42.0 kg
Sound pressure level66.5 dB(A)